Evacuated Blood Tubes
Evacuated Blood Tubes
Capped sterile tubes with an internal vacuum that are commonly used to collect venous blood specimens; products are available in various materials, with various stopper types, and anticoagulants.
Evacuated blood tubes are sealed, single-use, capped tubes used with suitable collection needles and tubing for the safe and sterile collection of blood samples from human or animal subjects. They are partially evacuated to facilitate blood draw when the collection needle punctures the cap. The closure caps may be color-coded, depending on the tube additives or specific purpose.
Evacuated blood tubes are typically made of plastics such as polypropylene or PET to minimize the risk of breakage, although glass evacuated blood tubes are also available. Available as plain, empty tubes, many are pre-loaded with additives or preservatives that stabilize the blood sample or contain gel separators to facilitate the separation of blood cells from serum or plasma.
Evacuated blood tubes are widely employed in hospital blood collection (phlebotomy) departments and in other clinical, veterinary, and research settings. Once filled, evacuated blood tubes can be securely stored or transported for subsequent analysis of serum, plasma, or whole blood by clinical chemistry, blood counts, or other tests.
Types of Evacuated Blood Collection Tubes
• Red top: plain tubes without additives; for serum samples
• Purple top: contain EDTA anticoagulant; for clinical hematology procedures
• Green top: contain heparin; for plasma samples
• Gray top: with added fluoride or oxalate; for glucose determinations
• Blue top: with sodium citrate; for coagulation testing
• Other additives and colored closures
- (3)
- (1)
- (6)
- (1)
- (1)
- (2)
- (10)
- (6)
- (1)
- (8)
- (6)
- (16)
- (1)
- (8)
- (1)
- (14)
- (1)
- (4)
- (3)
- (6)
- (2)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (6)
- (1)
- (2)
- (8)
- (3)
- (14)
- (3)
- (8)
- (3)
- (1)
- (1)
- (1)
- (1)
- (6)
- (1)
- (2)
- (1)
- (2)
- (1)
- (2)
- (1)
- (5)
- (1)
- (2)
- (2)
- (8)
- (45)
- (24)
- (1)
- (3)
- (33)
- (18)
- (1)
- (9)
- (2)
- (3)
- (2)
- (5)
- (1)
- (1)
- (2)
- (3)
- (13)
- (3)
- (1)
- (1)
- (2)
- (1)
- (1)
- (5)
- (6)
- (1)
- (1)
- (1)
- (3)
- (3)
- (2)
- (7)
- (2)
- (1)
- (1)
Filtered Search Results
Greiner Bio-One VACUETTE™ Heparin Blood Collection Tubes
VACUETTE™ Heparin Blood Collection Tubes have a green top and contain spray-dried lithium, sodium or ammonium heparin on the inner walls and are usedin clinical chemistry, immunology and serology. The anticoagulant heparin activates antithrombin, which blocks the clotting cascade and thus produces a whole blood/plasma sample.
For Use With (Equipment) | VACUETTE™ Blood Collection Needles |
---|---|
Product Type | Blood Collection Tube |
Material | PET |
Closure Color | Green with Black Ring |
For Use With (Application) | Blood Collection |
Closure Type | Non-ridged Pull Cap |
Sterility | Sterile |
BD Vacutainer™ Citrate Tube
Contains buffered trisodium citrate solution. BD™ Vacutainer™ Citrate Tube contains an anticoagulant additive equivalent to 3.2% trisodium citrate for coagulation investigations. It is also suitable for carrying out special test procedures, such as the platelet function test PFA-100.
Height (Metric) | 75 mm |
---|---|
Additive | Sodium Citrate |
Product Type | Venous Blood Sampling Coagulation Tube |
Diameter (Metric) Outer | 13 mm |
Closure Color | Light Blue |
Label Type | Block |
For Use With (Application) | Used for coagulation studies |
Closure Type | Hemogard |
BD Vacutainer™ Serum Tubes
Used to obtain a serum sample. BD™ Vacutainer™ Serum Tubes are made of durable PET plastic with a Hemogard™ closure. It has silica particles added to trigger coagulation, and are marked CAT and CE.
Additive | Silica |
---|---|
Product Type | Serum Tube |
Material | PET |
Certifications/Compliance | CE, CAT |
Closure Color | Red |
Label Type | Block |
For Use With (Application) | Used to obtain a serum sample |
Closure Type | Hemogard |
Greiner Bio-One VACUETTE™ K3EDTA Blood Collection Tubes
VACUETTE™ EDTA Blood Collection tubes are used for determinations in EDTA whole blood for haematology. Available with K2EDTA, K2EDTA Separator and K3EDTA. VACUETTE™ K3EDTA tubes contain tri-potassium K3EDTA which blocks the coagulation cascade.
Additive | K3 EDTA |
---|---|
For Use With (Equipment) | VACUETTE™ Blood Collection Needles |
Product Type | Blood Collection Tube |
Material | PET |
For Use With (Application) | Blood Collection |
Sterility | Sterile |
BD PAXgene™ Blood RNA Tube
Offers a convenient and closed system for the collection, storage and transportation of whole blood that requires intracellular RNA stabilization. BD Vacutainer™ PAXgene™ Blood RNA Tube is for in vitro diagnostic use and is CE-marked.
BD Vacutainer™ SST™ II Advance Tubes
Prevents the contamination of the serum from the separated cellular components. BD Vacutainer™ SST™ II Advance Tubes feature an inert, stable gel that separates the serum and the blood clot during centrifugation. The type of gel used enables short centrifugation times.
Additive | Silica |
---|---|
Product Type | Serum Separator Tube |
Material | PET |
Certifications/Compliance | CE |
For Use With (Application) | Used to obtain and separate a serum sample |
Closure Type | Hemogard |
Sterility | Sterile |
BD Vacutainer™ Glass Cell Preparation Tubes
Use for the one-step isolation of lymphocytes, monocytes, and plasma. BD™ Vacutainer™ Glass Cell Preparation Tubes allow for collection and processing of whole blood in a closed, sterile tube prepared with sodium citrate or sodium heparin as an anticoagulant.
Includes | Polyester gel, density gradient liquid |
---|---|
Product Type | Cell Preparation Tube |
Color | Clear |
Material | Glass |
Certifications/Compliance | CE |
Label Type | Transparent |
Closure Type | Speckled Conventional |
Sterility | Sterile |
Greiner Bio-One Serum Clot Activator Tubes
For routine clinical chemistry, immunohematology, serology or immunology testing
Additive | Microscopic Silica Particles |
---|---|
Material | Plastic |
Closure Type | Non-ridged Pull Cap |
BD Vacutainer™ Plastic Blood Collection Tubes for Trace Element Testing: K2EDTA, 10.8mg
Evacuated blood collection tubes for trace element testing
Greiner Bio-One VacuetteTube
Greiner Bio-One VacuetteTube, Capacity: 4mL, Closure Color: White, Closure Type: Cap, Sterile, Diameter Inside: 13mm, Height: 75mm, Vacuette Tube
Height (Metric) | 75 mm |
---|---|
Product Type | Vacuette Tube |
Diameter (Metric) Inner | 13 mm |
Closure Type | Cap |
Sterility | Sterile |
Greiner Bio-One Vacuette™ Glucose Blood Collection Tube FE Sodium Fluoride/K3EDTA
Vacuette™ Blood Collection Tubes have set the standard in today‘s marketplace. They provide improved safety and hygiene during specimen collection procedures with the advantage of being as clear as glass.
BD Vacutainer™ K3EDTA Tubes
Used to obtain a whole blood or EDTA plasma sample. BD Vacutainer™ K3EDTA Tubes are sterile, hematology tubes made of durable PET plastic with lavender Hemogard™ closures. Spray-dried postassium salt of EDTA is used as an anticoagulant.