Glass Fiber Filters and Prefilters
Glass Fiber Filters and Prefilters
- (53)
- (233)
- (64)
- (92)
- (4)
- (1)
- (12)
- (2)
- (44)
- (8)
- (1)
- (7)
- (8)
- (20)
- (10)
- (297)
- (1)
- (2)
- (37)
- (2)
- (2)
- (11)
- (18)
- (2)
- (49)
- (3)
- (19)
- (2)
- (11)
- (15)
- (61)
- (67)
- (30)
- (25)
- (212)
- (64)
- (1)
- (1)
- (8)
- (26)
- (3)
- (49)
- (1)
- (19)
- (1)
- (13)
- (20)
- (5)
Filtered Search Results
Fisherbrand™ Microglass Fiber Filter Discs
Made with 100% borosilicate micro-glass fibers. Fisherbrand™ Microglass Fiber Filter Discs are non-hygroscopic and biologically inert. They show chemical resistance to most solvents and reagents (except hydrofluoric acid).
Cytiva Whatman™ Binder-Free Glass Microfiber Filters GF/F Circles
Served as the basis filter for EPA standard for the toxicity characteristic leaching procedure. Whatman™ Binder-Free Glass Microfiber Filters GF/F Circles offers an extremely high loading capacity and flow rate.
Particle Retention | 0.7 μm |
---|---|
Temperature (English) Max. | 932°F |
Shape | Circle |
Description | Whatman Grade GF/F filter from Cytiva's business is manufactured from pure borosilicate glass. GF/F offers very fine particle retention and good loading capacity and flow rate. |
Temperature (Metric) Max | 500°C |
Grade | Grade GF/F |
Material | Borosilicate Glass |
For Use With (Application) | Recommended for DNA binding and purification.Very effective in filtering finely precipitated proteins.Can be used in conjunction with GF/D as a prefilter for the successful clarification of extremely ‘difficult’ biochemical solutions and fluids and nucl |
Thickness (Metric) | 420 μm |
Flow Rate | 19 sec./100mL/in.2 |
Type | Filter for TCLP Test Use |
Format | Disc |
Thickness (English) | 0.016 in. |
Autoclavable | Autoclavable |
Waterflow Rate | 41 mL/min |
Sartorius Stedim Biotech™ Glass Microfiber Filters, Discs, Grade MG 160
Binder-free glass microfiber filters suitable for analytical and gravimetric analyses.
Thickness (Metric) | 0.35 mm |
---|---|
Particle Retention | 1.2 μm |
Basis Weight | 75 g/m2 |
Format | Disc |
Filtration Time | 400 mL/min. |
Color | White |
Quantity | 50/Pk. |
Grade | MG 160 |
Material | Binder-free Glass Microfiber |
Hydrophobicity | Hydrophilic |
Sterility | Non-sterile |
Sartorius MGC Grade Glass Microfiber Filters without Binder
SureTRACE
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Binder free MGC Grade Glass Microfiber Filters are suitable for analytical and gravimetric analyses. They are also used as prefilter.
Thickness (Metric) | 0.25 mm |
---|---|
Particle Retention | 1.2 μm |
Temperature (English) Max. | 932°F to 1022°F |
Format | Disc |
Filtration Time | 66 sec. |
Air Resistance | 51 mbar |
Thickness (English) | 0.009 in. |
Temperature (Metric) Max | 500°C to 550°C |
Color | White |
Grade | MGC |
Material | Binder-free Glass Microfiber |
Sterility | Non-sterile |
Cytiva Whatman™ Binder-Free Glass Microfiber Filters, Grade 934-AH Circles
Designed for analysis of non-filterable residue and materials that require a high loading capacity glass microfiber filter. Whatman™ Binder-Free Glass Microfiber Filters, Grade 934-AH Circles are also used in cell harvesting, liquid scintillation, and monitoring pollution.
Particle Retention | 1.5 μm |
---|---|
Temperature (English) Max. | 932°F |
Shape | Circle |
Description | Whatman Grade 934-AH borosilicate glass microfiber filters from GE are smooth water quality filters with high retention efficiency. Grade 934-AH filters are often used in total suspended solids analysis. |
Filtration Time | 47 sec./100mL |
Quantity | 100 Pack |
Grade | Grade 934-AH |
Material | Borosilicate Glass |
Thickness (Metric) | 435 μm |
Flow Rate | 3.7 sec./100mL/in.2 |
Type | Filter for Total Suspended Solids Analysis |
Basis Weight | 64 g/m2 |
Format | Disc |
Thickness (English) | 0.017 in. |
Surface Type | Smooth |
Waterflow Rate | 341 mL/min |
Cytiva Whatman Grade 934-AH RTU Glass Microfiber Filters
Ready to use, Grade 934-AH RTU Glass Microfiber Filter Papers are the time-saving version of GE’s 934-AH glass microfiber filter papers, which are widely used for total suspended solids analysis.
Particle Retention | 1.5 μm |
---|---|
Quantity | 100 |
Grade | 934-AH RTU |
Material | Glass Microfiber |
Autoclavable | Not Autoclavable |
Sterility | Non-sterile |
Waterflow Rate | 341 mL/min |
Sartorius Glass Fiber (GF) Pre-filters
Use as a depth filter for larger totally filterable volumes. Sartorius Glass Fiber (GF) Pre-filters are made of borosilicate glass microfibers and are ideal for use as a pre-filter in clarification and sterile filtration. Available in a range of filter disc diameters.
Thickness (Metric) | 550 μm |
---|---|
Flow Rate | 295 to 381mL/min. |
Temperature (English) Max. | 428°F |
Format | Disc |
Temperature (Metric) Max | 220°C |
Color | White |
Grade | 13400 |
Material | Borosilicate Glass Microfiber |
Hydrophobicity | Hydrophilic |
For Use With (Application) | Used as a depth prefilter high particle loading capacity |
Autoclavable | Autoclavable |
Sterility | Non-sterile |
Cytiva Whatman Grade GF/F Glass Microfiber Filter
Binder-free borosilicate glass microfiber filter used for DNA purification, protein precipitation, and landfill leachate toxicity testing.
Cytiva Glass Fiber GF8 Filter
This glass fibre filter has an inorganic binder for the filtration of coarse particles
Sartorius Stedim Biotech™ Glass Microfiber Filters, Discs, Grade MGG
SureTRACE
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Binder-free glass microfiber filters for analytical and gravimetric analyses and prefiltering.
Thickness (Metric) | 0.28 mm |
---|---|
Particle Retention | 1.5 μm |
Basis Weight | 64 g/m2 |
Format | Disc |
Filtration Time | 600 mL/min. |
Color | White |
Quantity | 100/Pk. |
Grade | MGG |
Material | Binder-free Glass Microfiber |
Hydrophobicity | Hydrophilic |
Sterility | Non-sterile |
Cytiva Whatman™ Glass Fiber Filter Papers - Grade 31
Offers fine particle retention and high flow rate, as well as good loading capacity
Particle Retention | 2.7 μm |
---|---|
Filtration Time | 18sec. |
Air Resistance | 18.5mbar |
Temperature (Metric) Max | 500°C |
Color | White |
Quantity | 50 Pack |
Grade | MGD |
Material | Glass Microfiber |
For Use With (Application) | Recommended for analytical and gravimetric analyses and also as prefilters |
Sterility | Non-sterile |
Thickness (Metric) | 0.53 mm |
Type | Filter without Binder |
Basis Weight | 120 g/m2 |
Format | Disc |
Sartorius MGD Grade Glass Microfiber Filters w/o Binder
Binder free glass microfiber filters are suitable for analytical and gravimetric analyses. They are also used as prefilter.
Sartorius Stedim Biotech™ Glass Microfiber Filters, Grade MG 227/1/160
Generally used for air and gas monitoring, but are suitable as a prefilter.
Sartorius Stedim Biotech™ Glass Microfiber Filters, Discs, Grade MGC
Binder-free glass microfiber filters for analytical and gravimetric analyses and prefiltering.