Manual Gas Tight Syringes
Manual Gas Tight Syringes
Gas tight syringes for manual injections on GC instruments; includes fixed-needle, removable-needle formats in various sizes, needle gauges, needle point styles, and terminations; includes zero dead-volume and headspace syringes.
- (1)
- (18)
- (2)
- (26)
- (55)
- (1)
- (1)
- (120)
- (32)
- (92)
- (5)
- (1)
- (3)
- (1)
- (1)
- (11)
- (4)
- (37)
- (1)
- (1)
- (2)
- (67)
- (16)
- (84)
- (47)
- (35)
- (86)
- (11)
- (65)
- (3)
- (1)
- (1)
- (4)
- (136)
- (4)
- (10)
- (1)
- (58)
- (27)
- (14)
- (11)
- (54)
- (10)
- (1)
- (12)
- (9)
- (22)
- (42)
- (5)
- (2)
- (3)
- (201)
- (12)
- (12)
- (2)
- (3)
- (9)
- (107)
- (282)
- (1)
- (1)
- (8)
- (2)
- (2)
- (2)
- (2)
- (1)
- (72)
- (8)
- (15)
- (240)
- (13)
- (1)
- (73)
- (10)
- (194)
- (5)
- (1)
- (17)
- (1)
- (13)
- (4)
- (1)
- (124)
- (148)
- (49)
- (1)
- (2)
- (13)
- (1)
- (10)
- (44)
- (13)
- (36)
- (1)
- (75)
- (1)
- (4)
- (19)
- (64)
- (1)
- (1)
- (1)
- (1)
- (1)
- (2)
- (1)
- (6)
- (4)
- (9)
- (2)
- (16)
- (11)
- (1)
- (2)
- (11)
- (6)
- (6)
- (1)
- (12)
- (2)
- (1)
- (1)
- (1)
- (19)
- (4)
- (1)
- (1)
- (1)
- (2)
- (1)
- (9)
- (3)
- (13)
Filtered Search Results
Hamilton™ Modified 7000 Microliter™ Syringes
This series of syringes is ideal for dispensing volumes from 0.05 μL up to 5 μL. The 7000 series is the only zero dead volume syringe. The fine gauge plunger wire travels to the tip of the needle ensuring that all solvent is expelled from the needle.
Product Type | General Purpose Syringe |
---|---|
Diameter (Metric) Outer | 7.82 mm |
Connection Type | Knurled Hub, Removable |
Max. Temperature (English) | 239°F |
Diameter (English) Outer | 0.3 in. |
Quantity | Ea. |
Min. Temperature (English) | 50°F |
Length (English) Needle | 2.75 in. |
Max. Temperature (Metric) | 115°C |
Autoclavable | Autoclavable |
Min. Temperature (Metric) | 10°C |
Diameter (English) Outer Needle | 0.02 in. |
Trajan Scientific and Medical™ Diluter/Dispenser Syringes for Hamilton Microlab 500™
Gives better performance and superior quality. Trajan Scientific and Medical Diluter/Dispenser Syringes for Hamilton Microlab 500™ has the knowledge and expertise that goes into manufacturing an SGE syringe.
Includes | Plunger stop |
---|---|
Description | 60mm stroke, 6-32 UNC thread in plunger button |
Length (Metric) | 60 mm |
Product Type | Hamilton MicroLab 500™ Instrument Syringes |
Connection Type | Luer Lock |
Hamilton™ Modified 7000 Microliter™ Syringes
This series of syringes is ideal for dispensing volumes from 0.05 μL up to 5 μL. The 7000 series is the only zero dead volume syringe. The fine gauge plunger wire travels to the tip of the needle ensuring that all solvent is expelled from the needle.
Poulten & Graf GmbH FORTUNA™ Precision Gas Syringe
Poulten & Graf GmbH FORTUNA™ Precision Gas Syringe are used to measure gas volume.
Disposable | Reusable |
---|---|
Color | Clear |
Graduated | Yes |
Quantity | 1 |
Material | Glass (Tip),Neutral Glass,Neutral Glass (Barrel),Neutral Glass (Plunger) |
Autoclavable | Autoclavable |
Sterility | Non-sterile |
Graduations | Amber |
Thermo Scientific™ Fixed-Needle, Gas-Tight Syringes for GC Instruments
Choose Thermo Scientific™ Fixed-Needle, Gas-Tight Syringes for accurate, reproducible GC sample introduction using an affixed needle and a plunger that creates a tight seal.
Connection Type | Fixed |
---|
Thermo Scientific™ TriPlus RSH Autosampler Fixed GT Needle Syringe
Thermo Scientific™ TriPlus RSH Autosampler Fixed GT Needle Syringes are accurate and reproducible over a range of volumes.
Connection Type | Fixed |
---|---|
Material | Stainless Steel (Needle),Stainless Steel (Plunger) |
Length (Metric) Needle | 57 mm |
Thermo Scientific™ Manual, Fixed Needle, Gas Tight Syringes for GC Instruments
Choose Thermo Scientific™ Fixed-Needle, Gas-Tight Syringes for manual accurate, reproducible GC sample introduction using an affixed needle and a plunger that creates a tight seal.
Thermo Scientific™ Male Luer-LOK Priming Syringes
Thermo Scientific™ Male Luer-LOK Priming Syringes offer easy, accurate and reproducible manual injections.
Thermo Scientific™ Removable-Needle Autosampler Syringes for GC Instruments
Thermo Scientific™ Removable-Needle Autosampler Syringes for GC Instruments are accurate and reproducible over a range of volumes.
Thermo Scientific™ GC Syringe for CTC
Thermo Scientific™ Gastight GC Syringes are accurate and reproducible over a range of volumes.
Thermo Scientific™ TriPlus RSH Autosampler Fixed Needle Syringe, 100μL
Thermo Scientific™ TriPlus RSH Autosampler Fixed Needle Syringes are accurate and reproducible over a range of volumes.
Thermo Scientific™ Luer-Tip, Gas-Tight Manual Syringes for GC Systems
Get a gas-tight syringe for manual injections. This syringe features a Luer-Tip connection and is available in a variety of sizes.
Hamilton™ 701N Microliter Syringes
The 700 series syringe is the original hand-fitted Hamilton syringe. This series of syringes is ideal for dispensing volumes from 0.5 μL up to 500 μL. A variety of different terminations and needle options are available in this series.
Needle Point Number | 2 |
---|---|
Diameter (English) Inner | 0.019 in. |
Length (Metric) | 51 mm |
Volume (Metric) | 10 μL |
Length (English) | 2 in. |
Diameter (Metric) Inner | 0.048 cm |
Min. Temperature (English) | 50°F |
Material | Borosilicate Glass (Barrel),Stainless Steel (Plunger) |
Max. Temperature (Metric) | 50°C |
Max. Pressure | 137.9 bar |
Diameter (Metric) Inner Needle | 0.013 cm |
For Use With (Equipment) | Agilent 7670, 7671, and 7672 Automatic Liquid Sampler, Gas Chromatography Autosamplers |
Product Type | Microliter Autosampler Syringe |
Diameter (Metric) Outer | 0.66 cm |
Connection Type | Cemented |
Max. Temperature (English) | 122°F |
Diameter (English) Outer | 0.26 in. |
Model | 701 N |
Needle Point Style | Sharp, Bevel, Curved, Non-coring |
Diameter (Metric) Outer Needle | 0.047 cm |
Length (English) Needle | 2 in. |
Min. Temperature (Metric) | 10°C |
Needle Gauge | 26s G |
Diameter (English) Outer Needle | 0.018 in. |
Diameter (English) Inner Needle | 0.005 in. |
Hamilton™ 1700 Series Gastight™ Syringes: RN Termination
Gastight version of the original 700 series syringes, ideal for dispensing volumes from 1 up to 500μL
Length (Metric) | 51 mm |
---|---|
Product Type | Gastight Syringe |
Connection Type | Removable |
Max. Temperature (English) | 239°F |
Length (English) | 2 in. |
Quantity | Ea. |
Min. Temperature (English) | 50°F |
Material | Borosilicate Glass (Barrel),PTFE (Tip),Stainless Steel (Plunger) |
Length (English) Needle | 2 in. |
Max. Temperature (Metric) | 115°C |
For Use With (Application) | Ideal for dispensing both liquids and gases, useful for samples with dissolved or suspended molecules |
Autoclavable | Autoclavable |
Min. Temperature (Metric) | 10°C |
Hamilton™ 700 Microliter Syringes: N Termination
The 700 series syringe is the original hand-fitted Hamilton syringe. This series of syringes is ideal for dispensing volumes from 0.5 μL up to 500 μL. A variety of different terminations and needle options are available in this series.
Product Type | Microliter Syringe |
---|---|
Length (English) Needle | 2 in. |
For Use With (Application) | For dispensing low volumes to achieve the highest level of accuracy and precision possible |
Autoclavable | Not Autoclavable |