Learn More
Invitrogen™ NuPAGE™ Antioxidant
Proprietary reagent that maintains proteins in a reduced state during protein gel electrophoresis
Brand: Invitrogen™ NP0005
30.96 EUR valid until 2024-12-20
Use promo code "21651" to get your promotional price.
Includes: Contains 15mL NuPAGE Antioxidant
Description
Add to running buffer in the upper (cathode) buffer chamber when performing protein gel electrophoresis under reducing conditions.
- Use with samples reduced using NuPAGE Sample Reducing Agent or other reducing agents
- Optimized for neutral pH of NuPAGE Novex™ gels and is not compatible with other gel chemistries
- May also be added to NuPAGE Transfer Buffer to enhance transfer of proteins to membranes
- Migrates with reduced proteins to maintain reducing conditions and to prevent reoxidation of sensitive amino acids such as methionine and tryptophan
1D Gel Electrophoresis, Protein Gel Electrophoresis, Proteins, Expression, Isolation and Analysis
Order Info
Shipping Condition: Wet Ice
Specifications
Contains 15 ml NuPAGE™ Antioxidant. Store at 4°C. Guaranteed stable for 6 months unless otherwise specified in the product literature. | |
NuPAGE™ | |
Wet Ice |
Antioxidant | |
15 mL |
Safety and Handling
- NuPAGE Antioxidant
Signal Word
- Danger
Hazard Category
- Serious eye damage/eye irritation Category 2
- Reproductive toxicity Category 1B
Hazard Statement
- H315-Causes skin irritation.
Precautionary Statement
- P201-Obtain special instructions before use.
- P202-Do not handle until all safety precautions have been read and understood.
- P280-Wear protective gloves/protective clothing/eye protection/face protection.
- P264-Wash thoroughly after handling.
- P305+P351+P338-IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
- P337+P313-If eye irritation persists: Get medical advice/attention.
- P308+P313-IF exposed or concerned: Get medical advice/attention.
- P501-Dispose of contents/container to .
Supplemental information
- MIXTURE LIST-Contains : Dimethylformamide
Your input is important to us. Please complete this form to provide feedback related to the content on this product.
For Research Use Only. Not for use in diagnostic procedures.