Test
The Pierce BCA Protein Assay Kit is a high-precision, detergent-compatible protein assay for determination of protein concentration. Pierce BCA reagents provide accurate determination of protein concentration with most sample types encountered in protein research.
Assay | BCA Assay |
---|---|
For Use With (Equipment) | Spectrophotometer, Microplate Reader |
Product Type | Protein Quantitation Assay |
For Use With (Application) | Solution-based Detection, Absorbance |
Product Line | Pierce™ |
Detection Method | Colorimetric |
High-quality, calibrated BSA solutions (2 mg/mL) to serially dilute to create protein assay standard curves to accurately measure protein concentration.
Brown-to-purple (A595nm), ready-to-use, classic reducing agent-compatible assay reagent to measure total protein concentration vs. protein standard.
Special 3-component version of our popular BCA Reagents to measure total protein concentration of dilute protein solutions (0.5 to 20 micrograms/mL).
Brown-to-purple (A595nm), ready-to-use, fast reducing agent-compatible assay reagent to measure total protein concentration vs. protein standard.
The DynaMag-2 magnet combines a strong magnetic attraction for efficient separations in standard microcentrifuge tubes with a flexible and smart ergonomic design.
Estimate visually, or measure with a standard spectrophotometer or plate reader at 562 nm.
Assay | BCA Assay |
---|---|
Specificity | Not Target-Specific |
Content And Storage | Store at room temperature. |
Description | Pierce BCA Protein Assay Reagent A |
For Use With (Equipment) | Spectrophotometer, Microplate Reader |
Product Type | Protein Quantitation Assay |
For Use With (Application) | Solution-based Detection, Absorbance |
Product Line | Pierce™ |
Detection Method | Colorimetric |
The Pierce Bradford Plus Protein Assay Kit is a ready-to-use, reducing agent-compatible, improved Bradford assay reagent used to quickly measure total protein concentration compared to a protein standard.
Assay | Bradford Assay |
---|---|
For Use With (Equipment) | Spectrophotometer, Microplate Reader |
Product Type | Protein Quantitation Assay |
Sufficient For | 630 Tube Assays or 3160 Microplate Assays |
Quantity | 950 mL |
For Use With (Application) | Solution-based Detection, Absorbance |
Product Line | Pierce™ |
Detection Method | Colorimetric |
Green-to-blue (A562nm), two-component, precise, detergent-compatible assay reagent to measure total protein concentration vs. protein standard.
High-quality, calibrated BSA solutions (2mg/mL) to serially dilute to create protein assay standard curves to accurately measure protein concentration.
Dynabeads Protein A beads are uniform, 2.8-μm superparamagnetic beads with recombinant Protein A (∼45 kDa) covalently coupled to the surface.
Shipping Condition | Ambient temperature |
---|---|
Content And Storage | Dynabeads Protein A are supplied in PBS, pH 7.4 w/0.01% Tween-20, 0.09% NaN3 Store at 2–8°C. |
Purity or Quality Grade | For Research Use Only |
Description | Recombinant Protein A covalently bound to Dynabeads |
Surface Functionality | Protein A |
Material | Polystyrene |
Concentration | 30 mg/mL |
For Use With (Application) | Immunoprecipitation |
High-throughput Compatibility | High-throughput Compatible |
Ligand Type | Protein A |
Type | Superparamagnetic Beads |
Target | Antibodies |
Format | Beads in suspension |
For Use With (Equipment) | KingFisher™ Sample Purification System, DynaMag™ magnets |
Diameter (Metric) | 2.8 μm |
Certifications/Compliance | ISO9001 and ISO13485 |
Uniformity | Monosized 2.8 mm (CV <5%) |
Product Line | Dynabeads™ |
Quickly and reliably measure protein concentration of cell lysates or other samples that contain Triton™ X-100, NP-40 or other detergents using the the Thermo Scientific™ Pierce™ Detergent Compatible Bradford Assay Kit.
Dynabeads Protein G beads are uniform, 2.8-μm superparamagnetic beads with recombinant Protein G (∼17 kDa) covalently coupled to the surface.
Shipping Condition | Ambient temperature |
---|---|
Content And Storage | Dynabeads Protein G are supplied in PBS, pH 7.4 w/0.01% Tween-20, 0.09% NaN3 Store at 2–8°C. |
Purity or Quality Grade | For Research Use Only |
Description | Recombinant Protein G covalently bound to Dynabeads |
Surface Functionality | Protein G |
Material | Polystyrene |
Concentration | 30 mg/mL |
For Use With (Application) | Immunoprecipitation |
High-throughput Compatibility | High-throughput Compatible |
Ligand Type | Protein G |
Type | Superparamagnetic Beads |
Target | Antibodies |
Format | Beads in suspension |
For Use With (Equipment) | KingFisher™ Sample Purification System, DynaMag™ magnets |
Diameter (Metric) | 2.8 μm |
Certifications/Compliance | ISO9001 and ISO13485 |
Uniformity | Monosized 2.8 mm (CV <5%) |
Product Line | Dynabeads™ |
Multiplex with brighter, photostable, Alexa Fluor Antibody Labeling Kits without the intramolecular quenching. Conjugate antibodies to 9 available fluorophores for flow cytometry, ICC, IHC, IF, ELISA or HCS. Each kit contains enough dye to conjugate 100 μg per reaction with 5 reactions per kit.
Shipping Condition | Room Temperature |
---|---|
Product Type | Labeling Kit |
Solubility | DMSO (Dimethylsulfoxide) |
Labeling Method | Conjugation-based |
Label Type | Alexa Fluor |
Labeling Scale | 100 μg |
Chemical Reactivity | Amine |
Product Line | Alexa Fluor™ |
Detection Method | Fluorescence |
Designed for both automation platforms (e.g., Tecan) and manual workflows, but is compatible with PCR-strips and 96-well plates (200 μL), non-skirted and half-skirted.