Biochrom Ultrospec™ 30 Cell Density Meter
Ultrospec™ 30 Cell Density Meter for measuring density of bacteria and yeast cells in suspension.
Biochrom Printer Acccessory for Biochrom UV-Vis Spectrophotometers
Printer Acccessory compatible with BioDrop, Biowave, Lightwave, NanoVue, Simplinano and Genequant UV-Vis Spectrophotometers with Printer Option.
Biochrom Ultrospec™ 35c Colorimeter
Ultrospec™ 35c Colorimeter measures and records the concentration of solutions at set wavelengths
Biochrom Spare 560 nm Filter for Biochrom WPA CO7500 Colorimeter
Spare 560 nm Filter for Biochrom WPA CO7500 Colorimeter.
Biochrom Lightwave 3+
The Lightwave 3+ is a split beam UV/Vis spectrophotometer that combines ease of use with the flexibility of a 40 mm sample port. Expect exceptionally high resolution with the 3 nm bandwidth.
Shape | Round |
---|---|
Width (English) | 10 in. |
Photometric Linearity | ±1.3% or ±0.008 A (Whichever is Greater at 546 nm) |
Noise | ±0.005 peak to peak ±0.002 RMS |
Languages | English, French, German, Spanish, Italian, Chinese, Japanese |
Light Source | Xenon Flash |
Width (Metric) | 260 mm |
Detector Type | Twin CMOS Array |
Voltage | 120/240 V |
Stray Light | <0.5 %T 340 nm |
Photometric Repeatability | ±0.002 A to 0.5 A (at 546 nm) |
Weight (Metric) | 3 kg |
Height (English) | 3.9 in. |
Height (Metric) | 100 mm |
Beam Center Height | 15 mm |
Depth (English) | 15.3 in. |
Monochromator | Flat Grating |
Photometric Range | -0.3 to 2.5 A, 0.3 to 199 %T |
Wavelength Repeatability | ±1 nm |
Spectral Bandwidth | 3 nm |
Type | UV-Vis Spectrophotometer |
Wavelength Accuracy | ±2 nm |
Depth (Metric) | 390 mm |
Weight (English) | 6.6 lb. |
Wavelength Range | 190 to 1100 nm |
Product Line | Lightwave 3+ |
Display | Graphic LCD |
Biochrom Biowave 3+
The Biowave 3+ offers all the capabilities of a research grade UV/Vis spectrophotometer. Expect exceptionally high resolution with the 3 nm bandwidth. The robust design and reasonable cost make it great for students.
Height (Metric) | 100 mm |
---|---|
Beam Center Height | 15 mm |
Shape | Round |
Depth (English) | 15.3 in. |
Width (English) | 10 in. |
Photometric Linearity | ±1.3% or ±0.008 A (Whichever is Greater at 546 nm) |
Noise | ±0.005 peak to peak ±0.002 RMS |
Monochromator | Flat Grating |
Photometric Range | -0.3 to 2.5 A, 0.3 to 199 %T |
Wavelength Repeatability | ±1 nm |
Spectral Bandwidth | 3 nm |
Languages | English, French, German, Spanish, Italian, Chinese, Japanese |
Light Source | Xenon Flash |
Width (Metric) | 260 mm |
Detector Type | Twin CMOS Array |
Wavelength Accuracy | ±2 nm |
Depth (Metric) | 390 mm |
Voltage | 100/115/220/230 V |
Stray Light | <0.5 %T 340 nm |
Weight (English) | 6.6 lb. |
Photometric Repeatability | ±0.002 A to 0.5 A (at 546 nm) |
Wavelength Range | 190 to 1100 nm |
Weight (Metric) | 3 kg |
Height (English) | 3.9 in. |
Display | Graphic LCD |
Biochrom Biowave 3
The Biowave 3 offers all the capabilities of a research grade spectrophotometer with a robust design and a reasonable cost make it great for students.
Shape | Round |
---|---|
Width (English) | 10 in. |
Photometric Linearity | ±1.3% or ±0.008 A (Whichever is Greater at 546 nm) |
Noise | ±0.005 peak to peak ±0.002 RMS |
Languages | English, French, German, Spanish, Italian, Chinese, Japanese |
For Use With (Application) | UV/Vis Spectrophotometry |
Light Source | Xenon Flash |
Width (Metric) | 260 mm |
Detector Type | Twin CMOS Array |
For Use With (Equipment) | Microvolume Cuvettes |
Voltage | 100/115/220/230 V |
Stray Light | >0.5 %T 340 nm |
Photometric Repeatability | ±0.002 A to 0.5 A (at 546 nm) |
Weight (Metric) | 3 kg |
Height (English) | 3.9 in. |
Height (Metric) | 100 mm |
Beam Center Height | 15 mm |
Depth (English) | 15.3 in. |
Monochromator | Flat Grating |
Photometric Range | -0.3 to 2.5 A, 0.3 to 199 %T |
Wavelength Repeatability | ±1 nm |
Spectral Bandwidth | 5 nm |
Type | UV-Vis Spectrophotometer |
Wavelength Accuracy | ±2 nm |
Depth (Metric) | 390 mm |
Weight (English) | 6.6 lb. |
Wavelength Range | 190 to 1100 nm |
Product Line | Biowave 3 |
Display | Graphic LCD |
Biochrom WPA Biowave 3+ CT
The WPA Biowave 3+ CT offers all the capabilities of a research grade Life Sciences UV/Vis spectrophotometer. Expect exceptionally high resolution with the 3 nm bandwidth. The 5 in. color touch screen allows users to distinguish multiple samples by color on graph overlays and to focus on areas of interest.
Shape | Round |
---|---|
Width (English) | 10 in. |
Photometric Linearity | ±1.3% or ±0.008 A (Whichever is Greater at 546 nm) |
Noise | ±0.005 peak to peak ±0.002 RMS |
Languages | English, French, German, Spanish, Italian, Chinese, Japanese |
For Use With (Application) | UV/Vis Spectrophotometry |
Light Source | Xenon Flash |
Width (Metric) | 260 mm |
Detector Type | Twin CMOS Array |
For Use With (Equipment) | Low Volume UV Cuvettes |
Voltage | 120/240 V |
Stray Light | <0.5 %T 340 nm |
Photometric Repeatability | ±0.002 A to 0.5 A (at 546 nm) |
Weight (Metric) | 3 kg |
Height (English) | 3.9 in. |
Height (Metric) | 100 mm |
Beam Center Height | 15 mm |
Depth (English) | 15.3 in. |
Monochromator | Flat Grating |
Photometric Range | -0.3 to 2.5 A, 0.3 to 199 %T |
Wavelength Repeatability | ±1 nm |
Spectral Bandwidth | 3 nm |
Type | UV-Vis Spectrophotometer |
Wavelength Accuracy | ±2 nm |
Depth (Metric) | 390 mm |
Weight (English) | 6.6 lb. |
Wavelength Range | 190 to 1100 nm |
Product Line | WPA Biowave 3+ CT |
Display | Color Touchscreen |
Biochrom WPA Lightwave 3+ CT
WPA Lightwave 3+ CT is a split beam UV/Vis spectrophotometer that combines ease of use with the flexibility of a 40 mm sample port. Expect high resolution with the 3 nm bandwidth. Color touch screen for distinguishing multiple samples by color on graph overlays and to focus on areas of interest.
Shape | Round |
---|---|
Width (English) | 10 in. |
Photometric Linearity | ±1.3% or ±0.008 A (Whichever is Greater at 546 nm) |
Noise | ±0.005 peak to peak ±0.002 RMS |
Languages | English, French, German, Spanish, Italian, Chinese, Japanese |
Light Source | Xenon Flash |
Width (Metric) | 260 mm |
Detector Type | Twin CMOS Array |
For Use With (Equipment) | 10, 20, or 40 mm Pathlength Cells |
Voltage | 120/240 V |
Stray Light | <0.5 %T 340 nm |
Photometric Repeatability | ±0.002 A to 0.5 A (at 546 nm) |
Weight (Metric) | 3 kg |
Height (English) | 3.9 in. |
Height (Metric) | 100 mm |
Beam Center Height | 15 mm |
Depth (English) | 15.3 in. |
Monochromator | Flat Grating |
Photometric Range | -0.3 to 2.5 A, 0.3 to 199 %T |
Wavelength Repeatability | ±1 nm |
Spectral Bandwidth | 3 nm |
Type | UV-Vis Spectrophotometer |
Wavelength Accuracy | ±2 nm |
Depth (Metric) | 390 mm |
Weight (English) | 6.6 lb. |
Wavelength Range | 190 to 1100 nm |
Product Line | WPA Lightwave 3+ CT |
Display | Color Touchscreen |
Biochrom Lightwave 3
The Lightwave 3 is a split beam UV/Vis spectrophotometer that combines ease of use with the flexibility of a 40 mm sample port.
Shape | Round |
---|---|
Width (English) | 10 in. |
Photometric Linearity | ±1.3% or ±0.008 A (Whichever is Greater at 546 nm) |
Noise | ±0.005 peak to peak ±0.002 RMS |
Languages | English, French, German, Spanish, Italian, Chinese, Japanese |
Light Source | Xenon Flash |
Width (Metric) | 260 mm |
Detector Type | Twin CMOS Array |
Voltage | 120/240 V |
Stray Light | <0.5 %T 340 nm |
Photometric Repeatability | ±0.002 A to 0.5 A (at 546 nm) |
Weight (Metric) | 3 kg |
Height (English) | 3.9 in. |
Height (Metric) | 100 mm |
Beam Center Height | 15 mm |
Depth (English) | 15.3 in. |
Monochromator | Flat Grating |
Photometric Range | -0.3 to 2.5 A, 0.3 to 199 %T |
Wavelength Repeatability | ±1 nm |
Spectral Bandwidth | 5 nm |
Type | UV-Vis Spectrophotometer |
Wavelength Accuracy | ±2 nm |
Depth (Metric) | 390 mm |
Weight (English) | 6.6 lb. |
Wavelength Range | 190 to 1100 nm |
Product Line | Lightwave 3 |
Biochrom Calibration Fluid for NanoVue Plus Spectrophotometer
Use Calibration Fluid for NanoVue Plus Spectrophotometer to drop-and-measure sample plates for accurate and reliable quantitation of nucleic acid and protein sample with this Uracil solution in Sodium Azide.
Biochrom™ Ultrospec 7500 UV-Vis Spectrophotometer
The Ultrospec 7500 is a simple-to-use instrument with highly advanced performance functionality and a sophisticated GLP mode to ensure high quality, consistent and reliable results. Versatile and precise, this instrument is ideal for use in any manufacturing or production laboratory.
Biochrom Sample Plate Replacement Kit
Sample Plate Replacement Kit for use with NanoVue Plus Spectrophotometer.
Biochrom BioDrop μLITE+
The BioDrop μLITE+ microvolume sample port uses no moving parts. This means that the instrument provides excellent reproducibility without the need for expensive calibration, and no concern your results may stray over time.
Biochrom BioDrop Duo+
The BioDrop Duo+ is a Micro-Volume UV/Vis spectrophotometer with pre-programmed life science methods and general spectrophotometric capabilities. This 2-in-1 instrument will fulfill the needs of the most demanding laboratories.
Shape | Round |
---|---|
Wavelength Repeatability | ±1 nm |
Spectral Bandwidth | 5 nm |
Languages | English, French, German, Spanish, Italian, Chinese, Japanese |
Pathlength | 10 mm + 0.5 mm |
For Use With (Application) | General Spectrophotometry and Life Science Methodology |
Light Source | Xenon Flash |
Measurement Time | >4 Seconds |
Sample Volume (Metric) | Minimum 0.5 μL |
Type | Microvolume UV-Vis Spectrophotometer |
Dimensions (L x W x H) | 280 x 410 x 190 mm |
Wavelength Accuracy | ±2 nm |
Voltage | 120/240 V |
Stray Light | <0.5 %T at 220 nm NaI; <0.5 %T (at 340 nm NaNO2) |
Weight (English) | 7.9 lb. |
Photometric Repeatability | ±0.003 A (0 to 0.5 A); ±0.007 A (0.5 to 1.0 A) |
Interface | Touch Screen Display (Color), USB Port |
Wavelength Range | 190 to 1100 nm |
Weight (Metric) | 3.6 kg |
Product Line | BioDrop Duo+ |
Display | Color Touchscreen |