Test
Employ the most widely used MS phase in gas chromatography with the 5% phenyl phase Thermo Scientific™ TraceGOLD™ TG-5MS GC Column.
Stationary Phase | TraceGOLD™ TG-5 MS |
---|---|
USP Type | G27, G36 |
Choose these colums that feature a popular GCMS phase for many applications.
Stationary Phase | Trace™ TR-5 MS |
---|---|
Polarity | Non-Polar |
USP Type | G27, G36 |
Choose these excellent starting columns for method development, capable of performing most required separations.
Stationary Phase | Trace™ TR-5 |
---|---|
Polarity | Non-Polar |
USP Type | G27, G36 |
Choose these mid-polarity columns for GC/MS applications.
Max. Temperature | 360/370°C |
---|---|
Polarity | Mid-Polar |
USP Type | G3 |
Thermo Scientific™ TraceGOLD TG-VRX GC Columns provide good resolution and fast analysis times for volatile compounds.
Max. Temperature | 260°C |
---|---|
Stationary Phase | TraceGOLD™ TG-VRX |
Polarity | Non-Polar |
SGE GC column BP5MS is an optimized silphenylene column for general purpose MS analysis
Max. Temperature | 350°C |
---|---|
Description | GC Capillary column |
Temperature Range | -40°C to +330/350°C |
Material | 5% Phenyl Polysilphenylene-siloxane |
For Use With (Application) | 5% GC-MS Analysis |
Type | GC Capillary Column |
---|---|
Stationary Phase | Optima™ WAX |
Quantity | 1 Each |
Temperature Range | 240°C to 250°C |
USP Type | G16 |
Type | GC Capillary Column |
---|---|
Stationary Phase | Permabond™ FFAP |
Packing Material | Permabond™ FFAP |
Quantity | 1 Each |
Temperature Range | 220°C to 240°C |
USP Type | G25, G35 |
Optimize volatile organics analysis with this low-bleed, midpolarity GC column with high thermal stability.
Polarity | Mid-Polar |
---|---|
USP Type | G43 |
Analyze FAMEs with excellent thermal stability using this column.
Max. Temperature | 240/260°C |
---|---|
Stationary Phase | TraceGOLD™ TG-WAXMS |
Polarity | Polar |
USP Type | G14, G15, G16, G20, G39 |
Extend column lifetime and get more consistent results over a longer period of time.
Max. Temperature | 330/350°C (Standard Columns), 430°C (Metal Columns) |
---|---|
Stationary Phase | TraceGOLD™ TG-5 MS |
Polarity | Low-Polar |
Temperature Range | -60°C to +330/350°C |
For Use With (Application) | Active Compounds Analysis,GC/MS for Analysis of Active Compounds |
USP Type | G27, G36 |
Optimize separation when analyzing active environmental compounds with this low-bleed GC column with superior inertness.
Use this low-bleed, highly stable polar GC column for high-polarity separations for MS analysis.
Max. Temperature | 280/300°C |
---|---|
Stationary Phase | Trace™ TG-WAXMS |
Polarity | Polar |
For Use With (Application) | GC/MS for Aromatic Hydrocarbons, Alcohols, Esters, Aldehydes, and Ketones,GC/MS for Food Additives and Essential Oils |
USP Type | G16 |
Identify organic acids with high performance, sensitivity and reproducibility while preventing oxidative damage with this low-bleed, polar GC column.
Max. Temperature | 240/250°C |
---|---|
Stationary Phase | TraceGOLD™ TG-WAXMS A |
Polarity | Polar |
USP Type | G25, G35 |
Analyze a wide range of polar compounds with this low-bleed, general purpose, high polarity GC column.
Stationary Phase | Trace™ TR-WAX |
---|---|
Polarity | Polar |
USP Type | G16, G20 |