missing translation for 'onlineSavingsMsg'
Learn More

Thermo Scientific™ GeneBLAzer™ VPAC2-CRE-bla CHO-K1 Cells

GeneBLAzer™ VPAC2-CRE-bla CHO-K1 cells contain the human Vasoactive intestinal peptide/pituitary adenylate cyclase activating polypeptide receptor 2 (VPAC2) stably integrated into the CellSensor™ CRE-bla CHO-K1 cell line.

Brand:  Thermo Scientific™ K1706

Product Code. 10093913

  • 16300.00€ / Each
Estimated Shipment: 31-01-2025
to see stock.
Explore more special offers
Add to basket
This item is not returnable. View return policy

Description

Description

CellSensor™ CRE-bla CHO-K1 cells (Cat. no. K1535) contain a beta-lactamase reporter gene under control of the Cyclic AMP Response Element (CRE) response element.

The GeneBLAzer™ VPAC2-CRE-bla CHO-K1 cells are functionally validated for Z' and EC50 concentrations of VIP. In addition, GeneBLAzer™ VPAC2-CRE-bla CHO-K1 cells have been tested for assay performance under variable conditions. These data are found in the Validation & Assay Performance Summary.

VPAC2 has been implicated in a wide range of autoimmune and inflammation disorders, including Chronic obstructive pulmonary disease, Chronic Fatigue Syndrome. VPAC2 may also play a role in Type-2 diabetes.

TRUSTED_SUSTAINABILITY
Specifications

Specifications

NM_003382.3
Dividing Cells
Fluorescence
VPAC2
GeneBLAzer™
BLA (Beta-Lactamase)
CHO-K1
GPCR
Cell-based beta lactamase reporter gene
Contents:
K1706 GeneBLAzer™ VPAC2-CRE-bla CHO-K1 cells
(LiveBLAzer™-FRET B/G Loading Kit, Solution D and other materials are required separately; please refer to the protocol).
Includes:
• GeneBLAzer™ VPAC2-CRE-bla CHO-K1 cells
• GeneBLAzer™ VPAC2-CRE-bla CHO-K1 Assay Protocol
• Certificate of Analysis

Storage:
The GeneBLAzer™ VPAC2-CRE-bla CHO-K1 cells are shipped on dry ice and should be stored in liquid nitrogen immediately upon receipt.
FRET
Single Cell Clone Origin
2 x 106 Cells
VPAC2
GeneBLAzer™
Product Suggestions

Product Suggestions

Videos
SDS
Documents

Documents

Certificates
Promotions

Promotions

Product Content Correction

Your input is important to us. Please complete this form to provide feedback related to the content on this product.

Product Title

By clicking Submit, you acknowledge that you may be contacted by Fisher Scientific in regards to the feedback you have provided in this form. We will not share your information for any other purposes. All contact information provided shall also be maintained in accordance with our Privacy Policy.

Thank You! Your feedback has been submitted. Fisher Scientific is always working to improve our content for you. We appreciate your feedback.

For Research Use Only. Not for use in diagnostic procedures.