BTX™ Tweezertrode™ Electrode Kit

Product Code. 15487280
Click to view available options
Diameter (Metric):
7 mm
10 mm
Unit Size:
Each
This item is not returnable. View return policy

Product Code. 15487280

Brand: BTX™ 450165

Please to purchase this item. Need a web account? Register with us today!

This item is not returnable. View return policy

Tweezertrode™ Electrode Kit features reusable, tweezer-style, in vivo electrodes suitable for drug or gene delivery in animals.

  • Consist of a standard 11.5 cm tweezer modified with disk electrodes of stainless steel or platinum at the tip
  • Compatible with BTX Gemini X2 and ECM-2001 Electroporation Systems
  • Gap between electrode disks may be adjusted from 1 mm to more than 2 cm
  • Can be easily cleaned
  • Kits are supplied with BTX524 coaxial cable for connection to electroporation generators

Specifications

For Use With (Application) In vivo applications, including in utero and ex-vivo gene transfection, eletroporation therapy, and transdermal drug delivery.
For Use With (Equipment) ECM 830, Gemini X2, ECM 2001+, Legacy ECM 2001 Generator
Material Stainless Steel
Product Line BTX Electroporation
Product Type Electrode Kit
Voltage 1000 V
Description Stainless Tweezertrode Kit, 7 mm
Diameter (English) 0.27 in.
Diameter (Metric) 7 mm
Electrode Shape Circular
Includes Cable
Length (English) 0.27 in.
Length (English) Electrode 0.47 in.
Length (Metric) 7 mm
Length (Metric) Electrode 12 mm
Pulse Length Range 10 μsec. to 99 msec. in PBS
Quantity 1 Ea.
Relative Humidity 20 to 80%
Size (English) Gap <0.04 in. to >0.79 in.
Size (Metric) Gap <1 mm to >2 cm
Tweezer Size 11.5 cm
Sterility Non-sterile
Connection Type Banana Cables
Pulse Form Square Wave
Mehr anzeigen Weniger anzeigen

Intended for Research use only. Not for use in diagnostic or clinical procedures.

Berichtigung von Produktinhalten

Bitte geben Sie uns Ihr Feedback zu den Produktinhalten, indem Sie das folgende Formular ausfüllen.

Name des Produkts

Indem Sie auf Absenden klicken, erklären Sie sich damit einverstanden, dass Fisher Scientific sich mit Ihnen in Verbindung setzen kann, um Ihr Feedback in diesem Formular zu bearbeiten. Wir werden Ihre Informationen nicht für andere Zwecke weitergeben. Alle bereitgestellten Kontaktinformationen werden in Übereinstimmung mit unserer Datenschutzrichtlinie aufbewahrt. Datenschutzrichtlinie.