GE Whatman Filtration for HPLC Sample Preparation

GE_HPLC_Landing_Banner

Simplify sample preparation with the Whatman™ regenerated cellulose membrane portfolio from GE Healthcare

Please find in the training section, interesting papers relating to analytical HPLC from GE

Overview

Accurate. Reliable. Fast

  • Reduce cost with well-designed devices – the regenerated cellulose (RC) family includes products for robotic sample handing, outside-of-lab sample preparation, certified method development, and working with hard-to-filter samples.
  • Increase accuracy with reliable, repeatable results – The RC family is demonstrated to have extremely low levels of chemical extractables that could interfere with analysis. Products are available to retain a variety of particle sizes.
  • Save time with multifunctional products – reduce time spent deciding which membrane type to use for your sample preparation. The RC membrane is broadly compatible with common HPLC sample solvents and mobile phases.
  • Improve efficiency with ready-to-use products – RC products are supplied ready for use. The hydrophilic, low-protein binding RC membrane is suitable for a wide variety of HPLC applications.

Characteristics of common membranes

Solvent compatibility

Qualities

Membrane1

Aqueous

Nonaqueous

Low protein binding

Low extractables

RC++++++++++++
CA+++-++++
ME+++++-
CN+++---
PVDF++++++++++
PP++++++--
NYL++++--
PES++++++++++
PTFE-+++-+
Anopore™++++++++++
PC++++++++++
1 RC = regenerated cellulose; CA = cellulose acetate; ME = mixed ester; CN = cellulose nitrate; PVDF = polyvinylidene fluoride; PP = polypropylene; NYL = nylon; PES = polyethersulfone; PTFE = Polytetrafluoroethylene; PC = polycarbonate.
+++ strong characteristic
+ weak characteristic
- does not have characteristi
RC Membrane

Mobile phase filtration

RC_Membrane

Whatman RC55 and GV 050/2 vacuum filtration unit for solvent filtration

Use the same material for mobile phase filtration and sample filtration to:

  • Reduce variation of analysis
  • Reduce rate of column clogging
  • Enhance lifetime of column
If inline degassing is required, consider the Whatman Inline filter/de-gasser. Choose from two membrane options:
  • Nylon – when mobile phase is > 20% aqueous
  • Polypropylene – for non-aqueous solvents

RC Membrane

Buy Now

Product sample:

Request Now
Puradisc Filters

Preventive care: Puradisc filters

Filtration of your samples is important as a preventive maintenance step for HPLC or UHPLC analysis. Keep unwanted particulate matter from entering the injector to increase column life, shorten run time, and optimize peak shape.

  • Manufactured to a high standard in GE’s ISO 9001:2008 certified facilities
  • Available in non-RC membrane types to support a variety of other applications
Puradisc_Filters

Typical data

Puradic Syringe Filters

 

4 mm diameter*

30 mm diameter*

HousingPolypropylenePolycarbonate
Filtration area0.2 cm25.7 cm2
Maximum pressure75 psi (5.2 bar)100 psi (6.9 bar)
Volume ‘hold up’ with air purge< 10 μl< 50 μl
Dimensions10.1 × 23.5 mm
19.5 × 7.7 mm
(PVDF membrane only)
26 × 34 mm
Weight (approx)0.55 g4.7 g
Volume throughputup to 2 mlup to 100 ml
Inlet connectionFemale Luer lockFemale Luer lock
Outlet connectionMale Luer/tube tipMale Luer/tube tip
Sterilization§Autoclave at 121°CAutoclaving not recommended
*Diameters available for Puradisc only.
§Applies to nonsterile filters only. Do not autoclave sterile filters

30mm Puradisc Syringe Filters

Buy Now

4mm Puradisc Syringe Filters

Buy Now

Product sample:

Request Now
Spartan Filters

Certified quality for method development: SPARTAN filters

Spartan_Filters

SPARTAN brand syringe filters are HPLC-certified for confidence and consistent results. Tested and certified for the absence of UV-absorbing substances (210 and 254 nm) with water, methanol, acetonitrile to ensure absence of interfering substances.

  • Hydrophilic, low protein-binding membrane made of regenerated cellulose
  • Excellent chemical resistance against the standard aqueous and organic HPLC solvents
  • Tested and certified for the absence of UV-absorbing substances at wavelengths of 210 and 254 nm with water, methanol, and acetonitrile
  • 13 mm diameter with Mini-Tip options
  • 13 mm diameter with extremely low dead volume < 10 μL

Spartan filters 13mm diameter

Buy Now

Spartan filters 30mm diameter

Buy Now

Product sample:

Request Now
Whatman GDX

High-particulate, challenging sample filtration: Whatman GD/X filters

Whatman_GDX_Final

Filter even the most difficult samples and use less hand pressure with GD/X syringe filters.

  • Exceptional loading capacity and fast flow rates – prevents back pressure and clogging of membrane
  • Graduated microfiber prefilter from 1 μm to 0.7 μm
  • Higher flow rates (3×) compared to unprotected membranes
  • Uses glass microfiber-based prefilters
For metals testing and other applications where glass-based compounds could interfere with analysis, we offer a related syringe filter (GD/XP), which uses polypropylene prefilters.

Typical data

Whatman GD/X Syringe Filters

Membrane

GD/X 13 mm

GD/X 25 mm

HousingPolypropylene (pigment-free)Polypropylene (pigment-free)
Filtration area1.3 cm24.6 cm2
Maximum pressure100 psi (6.9 bar)75 psi (5.2 bar)
Volume “hold-up” full housing with air purge0.5 ml 50 μl (approx)1.4 ml 250 μl (approx)
Dimensions21.6 × 29.8 mm20.8 × 29.8 mm
Weight3 g (approx)3 g (approx)
Flow directionFlow should enter from the inletFlow should enter from the inlet
Inlet connectionFemale Luer lockFemale Luer lock
Outlet connectionMale LuerMale Luer
Sterilization*Autoclave at 121°C at 15 psi for 20 minAutoclave at 121°C at 15 psi for 20 min
Glass microfiber prefiltration media100% borosilicate GMF 150: 1 μm GF/F 0.7 μm100% borosilicate GMF 150: 1 μm GF/F 0.7 μm
*Applies to nonsterile filters only. Do not autoclave sterile GD/X filters.

Typical data

GD/XP Syringe Filters

 

GD/XP 13 mm

HousingPolypropylene (pigment-free)
Filtration area4.6 cm2
Maximum pressure75 psi (5.2 bar)
Volume “hold-up” full housing1.4 ml with air purge 250 μl (approx)
Dimensions20.8 × 29.8 mm
Weight3 g (approx)
Flow directionFlow should enter from the inlet
Inlet connectionFemale Luer lock
Outlet connectionMale Luer
SterilizationAutoclave at 121°C at 15 psi for 20 min
Prefiltration mediaPP 20 μm: 5 μm
Not recommended for nylon.
Whatman_GDX_Diagram

Whatman GD/X 13mm diameter

Buy Now

Whatman GD/X 25mm diameter

Buy Now

Whatman GD/XP 25mm diameter

Buy Now

Product sample:

Request Now
Mini-UniPrep™

Autosampler and workflow support: Mini-UniPrep filters

Whatman Mini-UniPrep Syringeless Filters - polypropylene or glass chambers

Mini_UniPrep

The Mini-UniPrep syringeless filters are compatible with most autosamplers.

  • Easy-to-use design supports sample preparation outside of the lab if needed
  • Process samples in one-third the time of traditional syringe filtration
  • Replaces syringe, syringe filter, vial, and cap in one consumable
  • Polypropylene or glass chamber options to prevent interference from chemical leaching
  • Amber vials available for light sensitive samples
  • Multi-compressors available for ease of use
  • 12 × 33 mm vial can be used to filter up to 400 μL
Mini_UniPrep_Parts

Typical data

Mini-UniPrep and Mini-UniPrep G2 filter vials

 

Mini-UniPrep

Mini-UniPrep G2

DimensionsEquivalent in size to 12 mm × 32 mm vialsEquivalent in size to 12 × 32 mm vials
Materials of construction  
Chamber:PolypropyleneBorosilicate glass
Plunger housing:PolypropylenePolypropylene
Plunger inner storage vialN/ABorosilicate glass/td>
Filter medium:As specifiedAs specified
Septum:Silicone with PTFE linerSilicone with PTFE liner
Cap:PolypropylenePolypropylene
Maximum operating temp50°C (122°F)50°C (122°F)
Max. unfiltered sample capacity400 μL500 μL
Max. filtered sample capacity350 μL330 μL
Dead volume50 μL170 μL
Recommended minimum filtering volume100 μL220 μL placed in the chamber to obtain 50 μL in inner storage vial
Nominal force needed to compressApprox. 8.2 kg (18 lbs)Approx. 11.3 kg (25 lbs)
Autosampler needle height adjustment:3 mm from the bottom of Mini-UniPrep5 mm from the bottom of Mini-UniPrep G2
Autosampler compatibilityAny autosampler that accommodates standard 12 × 32 mm profile vialsAny autosampler that accommodates standard 12 × 32 mm profile vials

Mini-UniPrep Compressors

Buy Now

Mini-UniPrep filter vial polypropylene housing 0.2um pore size

Buy Now

Mini-UniPrep filter vial polypropylene housing 0.45um pore size

Buy Now

Mini-UniPrep G2 filter vials with inner glass storage vial 0.2um pore size

Buy Now

Mini-UniPrep G2 filter vials with inner glass storage vial 0.45um pore size

Buy Now

Product sample:

Request Now
Education

Sample Preparation for HPLC Survey Report*

*A qualified survey of 303 readers of The Analytical Scientist conducted exclusively for GE Healthcare

Download file

Request your sample
  • 2Email Address
  • Order your free samples today so you can see for yourself how Whatman™ products can simplify your sample preparation.

    There are over 100 samples available to choose from within the regenerated cellulose membrane portfolio. Please select up to a total of four samples by clicking on the products below. You can use the drop down box and search functionality to assist you. Once you have selected your products please click the next step button, where you will be asked to complete your contact details. If you've accidentally selected the wrong sample, simply click it on the right-hand side to deselect.

    Please note: The sample pack sizes that are supplied are based on our current products, the pack sizes will not be/reflect the standard quantity sold in a selected product pack.

    No product selected
    No product selected
    No product selected
    No product selected
    Terms & Conditions
    1. 1. Restrictions apply. Offer limited to x 4 samples per customer.
    2. 2. By registering, you warrant that you are not prohibited by employment, contract, or law from accepting a gift from GE Life Sciences.
    3. 3. Healthcare professionals may not participate in this promotion.
    4. 4. GE and the GE monogram are trademarks of General Electric Company.
    5. 5. GE reserve the right to amend this offer at any time.
    6. 6. The sample pack sizes that are supplied are based on our current products, the pack sizes will not be/reflect the standard quantity sold in a selected product pack.
    7. 7. Free samples are not available to customers in Italy.