Spectral Bandwidth | 2 nm |
---|
Thermo Scientific™ GENESYS™ 140/150 Vis/UV-Vis Spectrophotometers
Get the most for your QA/QC or teaching lab with a rugged, network ready spectrophotometer designed for repetitive measurements and ease of use.
Thermo Scientific™ Evolution™ One/One Plus UV-Vis Spectrophotometers
Thermo Scientific™ Evolution™ UV-Vis Spectrophotometers combine reliable and versatile hardware with easy-to-learn, easy-to-use Thermo Scientific™ Insight™ Pro Software. Together they will meet the diverse needs your organization requires from an analytical tool.
Thermo Scientific™ GENESYS™ 180 UV-Vis Spectrophotometer, EU power cable
Perform UV-Vis measurements with a double beam with a reference cell position with the Thermo Scientific GENESYS 180 UV-Vis spectrophotometer.
Implen™ NanoPhotometer™ N60 Micro-Volume UV-VIS Spectrophotometer
The Implen NanoPhotometer™ N60 UV/Vis spectrophotometer for NanoVolume applications. Quantify DNA, RNA, proteins and scan other samples within seconds.
Connections | 2x USB A, USB B, HDMI, Ethernet, WiFi |
---|---|
Processor | Linux based NPOS |
Spectral Bandwidth | <1.8 nm |
Languages | English, French, German, Spanish, Portuguese, Russian, Chinese, Japanese |
Absorbance Range | 0.02 to 330 A |
Pathlength | 0.67 and 0.07 mm |
For Use With (Application) | Nucleic Acids, Protein UV, Protein Assays, Kinetics, OD600, Wavelength, Wavescan, Standard Curve, Absorbance Ratio, Concentration, Custom |
Light Source | Xenon Flash |
Measurement Time | 2.5 to 4.0 sec |
Sample Volume (Metric) | 0.3 to 2 μL |
Detector Type | 3648-element CCD Array |
Dimensions (L x W x H) | 20 x 20 x 12 cm |
Wavelength Accuracy | ± 0.75 nm |
No. of Samples | 1 |
System Requirements | Windows 7, 8, 10 (32 & 64 bit); OS X, iOS; Android OS |
Voltage | 90/250 V |
Stray Light | < 0.5% @ 240 nm using NaI |
Absorbance Accuracy | < 1.75% at 0.7 A at 280 nm of the reading |
Wavelength Range | 200 to 900 nm |
Measurement Range | 1 to 16,500 ng/μL |
Display | 7 in. Glove Compatible Touchscreen, 1024 x 600 pixels |
Implen™ NanoPhotometer™ C40 Cuvette UV-VIS Spectrophotometer
For cuvette applications. Suitable for all common photometric measurements like protein assays, kinetics and standard curve. Intuitive touchscreen operation, small footprint and network integration for convenient lab bench operation. Recalibration-free patented technology.
Connections | 2x USB A, USB B, HDMI, Ethernet, WiFi |
---|---|
Operating Temperature | 37 °C ± 0.5 °C |
Beam Center Height | 8.5 mm |
Processor | Linux based NPOS |
Spectral Bandwidth | <1.8 nm |
Languages | English, French, German, Spanish, Portuguese, Russian, Chinese, Japanese |
Absorbance Range | 0 to 2.6 A |
Pathlength | 10, 5, 2, 1, 0.5 mm |
For Use With (Application) | Nucleic Acids, Protein UV, Protein Assays, Kinetics, OD600, Wavelength, Wavescan, Standard Curve, Absorbance Ratio, Concentration, Custom |
Light Source | Xenon Flash |
Measurement Time | 2.5 sec |
Detector Type | 3648-element CCD Array |
Type | Spectrophotometer |
Dimensions (L x W x H) | 200 x 200 x 120 mm |
Wavelength Accuracy | ± 0.75 nm |
No. of Samples | 1 |
System Requirements | Windows 7, 8, 10 (32 & 64 bit); OS X, iOS; Android OS |
Voltage | 90/250 V |
Absorbance Accuracy | < 1.75 % at 0.7 A (0.67 mm path) at 280 nm of the reading |
Wavelength Range | 200 to 900 nm |
Display | 7 in. Glove Compatible Touchscreen, 1024 x 600 pixels |
Implen™ NanoPhotometer™ NP80 Nano-Volume and Cuvette UV-VIS Spectrophotometer
The Implen NanoPhotometer™ NP80 UV/Vis spectrophotometer for NanoVolume and cuvette applications. Quantify DNA, RNA, proteins and scan other samples within seconds.
Connections | 2x USB A, USB B, Ethernet, WiFi |
---|---|
Operating Temperature | 37 °C ± 0.5 °C Cuvette |
Beam Center Height | 8.5 mm |
Processor | Linux based NPOS |
Spectral Bandwidth | <1.8 nm |
Languages | English, French, German, Spanish, Portuguese, Russian, Chinese, Japanese |
Absorbance Range | 0.02 to 330 A NanoVolume, 0 to 2.6 A Cuvette |
Pathlength | 0.67 and 0.07 mm |
For Use With (Application) | Nucleic Acids, Protein UV, Protein Assays, Kinetics, OD600, Wavelength, Wavescan, Standard Curve, Absorbance Ratio, Concentration, Custom |
Light Source | Xenon Flash |
Measurement Time | 2.5 to 4.0 sec |
Sample Volume (Metric) | 0.3 to 2 μL |
Detector Type | 3648-element CCD Array |
Dimensions (L x W x H) | 20 x 20 x 12 cm |
Wavelength Accuracy | ± 0.75 nm |
No. of Samples | 1 |
System Requirements | Windows 7, 8, 10 (32 & 64 bit); OS X, iOS; Android OS |
Voltage | 90/250 V |
Stray Light | < 0.5% @ 240 nm using NaI |
Absorbance Accuracy | < 1.75% at 0.7 A at 280 nm of the reading |
Wavelength Range | 200 to 900 nm |
Measurement Range | 1 to 16,500 ng/μL |
Display | 7 in. Glove Compatible Touchscreen, 1024 x 600 pixels |
Implen™ NanoPhotometer™ N120 Multichannel Micro-Volume UV-VIS Spectrophotometer
The Implen NanoPhotometer™ N120 scans up to 12 samples in just 20 seconds. Quantifying DNA, RNA and proteins has never been faster. Intuitive touchscreen operation, small footprint and network integration for convenient lab bench operation. Recalibration-free patented technology Made in Germany.
Processor | Linux based NPOS |
---|---|
Spectral Bandwidth | <2.5 nm |
Languages | English, French, German, Spanish, Portuguese, Russian, Chinese, Japanese |
Absorbance Range | 0.04 to 160 A |
Pathlength | 1 and 0.125 mm |
For Use With (Application) | Nucleic Acids, Protein UV, Protein Assays, Kinetics, OD600, Wavelength, Wavescan, Standard Curve, Absorbance Ratio, Concentration, Custom |
Light Source | Xenon Flash |
Measurement Time | 1.7 - 2.5 seconds |
Sample Volume (Metric) | 2 to 3.5 μL |
Detector Type | 3648-element CCD Array |
Dimensions (L x W x H) | 20 x 20 x 12 cm |
Wavelength Accuracy | ± 0.75 nm |
No. of Samples | 1 to 12 |
System Requirements | Windows 7, 8, 10 (32 & 64 bit); OS X, iOS; Android OS |
Voltage | 90/250 V |
Stray Light | < 1% @ 240 nm using NaI |
Wavelength Range | 200 to 900 nm |
Display | 7 in. Glove Compatible Touchscreen, 1024 x 600 pixels |
Implen™ NanoPhotometer™ N50-Touch Micro-Volume UV-VIS Spectrophotometer
The Implen NanoPhotometer™ N50 UV/Vis spectrophotometer for NanoVolume applications. Quantify DNA, RNA, proteins and scan other samples within seconds. Intuitive touchscreen operation, small footprint and network integration for convenient lab bench operation.
HYDRANAL™-Solvent E, Honeywell Fluka™
Medium for volumetric two-component Karl Fischer titration (ethanol-based)
CAS | 7446-09-5 |
---|---|
MDL Number | MFCD01867183 |
Health Hazard 2 | P201-P210-P280-P308 + P313-P370 + P378-P403 + P235 |
Flash Point | 12°C (53.6°F) |
UN Number | UN1170 |
Chemical Name or Material | HYDRANAL™-Solvent E |
Density | 0.90g/mL |
HYDRANAL™ - Formamide dry, Solvent for KF titration, Honeywell Fluka™
CAS: 75-12-7 Molecular Formula: CH3NO Molecular Weight (g/mol): 45.04 MDL Number: MFCD00007941 InChI Key: ZHNUHDYFZUAESO-UHFFFAOYSA-N PubChem CID: 713 ChEBI: CHEBI:48431 IUPAC Name: formamide SMILES: NC=O
PubChem CID | 713 |
---|---|
CAS | 75-12-7 |
Molecular Weight (g/mol) | 45.04 |
ChEBI | CHEBI:48431 |
MDL Number | MFCD00007941 |
SMILES | NC=O |
IUPAC Name | formamide |
InChI Key | ZHNUHDYFZUAESO-UHFFFAOYSA-N |
Molecular Formula | CH3NO |
Thermo Scientific™ Orion™ AquaMate Vis and UV-Vis Spectrophotometers
Optimized for your water analysis needs AquaMate 7100 Vis and AquaMate 8100 UV-Vis Spectrophotometers provide fast and reliable results
Photometric Accuracy | ±0.002 A at 0.5 A, ±0.004 A at 1.0 A, ±0.008 A at 2.0 A |
---|---|
Connections | Single USB-A Export data to network or PC via USB, Ethernet, or Wi-Fi USB adaptor, available Print via USB, Ethernet or Wi-Fi USB adaptor available |
Height (Metric) | 19.5 cm |
Electrical Requirements | External AC to DC converter. Voltage and Frequency (Hz) selected automatically, 100/240 V, 50/60 Hz |
Warranty | 1 Year |
Length (Metric) | 35.5 cm |
Noise | (RMS at 500 nm 60 consecutive measurements) ≤0.00020A at 0A at 260 and 500 nm ≤0.00030A at 1A at 260 and 500 nm ≤0.00040A at 2A at 260 and 500 nm |
Wavelength Repeatability | < ±0.2 nm |
For Use With (Application) | Water and Waste Water Analysis |
Width (Metric) | 38.5 cm |
Detector Type | Dual Silicon Photodiodes |
Dimensions (L x W x H) | 35.5 x 38.5 x 19.5 cm |
Wavelength Accuracy | ±0.5 nm |
Depth (Metric) | 35.5 cm |
Compartments | Accessible from top, front or side Able to accommodate cells up to 100 mm cells Available accessory for test tubes up to 25 mm diameter and 150 mm height Removable, washable sample compartment liner with magnetic placement and hold-down |
Keypad | Glove- friendly touchscreen |
Certifications/Compliance | CE / TUV |
Optical Design | Double Beam |
Photometric Repeatability | ±0.001A at 1A measured at 1.0A at 546 nm |
Interface | Glove friendly touch-screen |
Weight (Metric) | 7.5 kg |
Wavelength Data Interval | 0.2 nm, 0.5 nm, 1 nm, 2 nm, 5 nm |
Display | 7 in. High Definition Color Touchscreen, Fixed, 800 x 1280 pixels |