Hydrophobic Interaction Chromatography Reagents and Supplies
Hydrophobic Interaction Chromatography Reagents and Supplies
- (1)
- (1)
- (2)
- (1)
- (1)
- (9)
- (9)
- (2)
- (1)
- (1)
- (1)
- (2)
- (2)
- (2)
- (1)
- (2)
- (2)
- (2)
- (2)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
Filtered Search Results
Cytiva HiTrap™ Capto™ HIC Selection Kit
Five Capto™ Hydrophobic Interaction Chromatography Resins in HiTrap™ Columns for resin selection and screening protein purification conditions
Particle Size | 45 to 165 μm |
---|---|
Ligand Type | Butyl |
Height (Metric) | 25 mm |
pH Range | 3 to 13 |
Product Type | HiTrap Butyl FF |
Material | Polypropylene |
Storage Requirements | 4°C to 30°C, 20% Ethanol |
For Use With (Application) | For Screening of Selectivity, Binding and Elution Conditions, as Well as Small Scale Purifications |
Support Type | 4% Cross-linked Agarose |
Media Type | Butyl Sepharose 4 Fast Flow |
Max. Pressure | 5 bar [0.5 MPa] (70 psi) |
Height (English) | 0.984 in. |
Cytiva HiTrap™ Butyl-S FF Columns
Designed for purification of relatively strong hydrophilic molecules at low salt concentrations
Particle Size | 45 to 165 μm |
---|---|
Ligand Type | Butyl-S |
pH Range | 3 to 13 |
Product Type | HiTrap Butyl-S FF column |
Material | Polypropylene |
Support Type | 6% Cross-linked Agarose |
Cytiva HiTrap™ Phenyl HP Columns
Prepacked columns for convenient and fast separations. Cytiva Lifescience™ HiTrap™ Phenyl HP Columns are designed for use with a syringe, laboratory pump or chromatography system.
Particle Size | 24 to 44 μm |
---|---|
Ligand Type | Phenyl |
pH Range | 3 to 13 |
Product Type | HiTrap Phenyl HP |
Material | Polypropylene |
Storage Requirements | 4°C to 30°C, 20% Ethanol |
For Use With (Application) | For Screening of Selectivity, Binding and Elution Conditions, as Well as Small Scale Purifications |
Support Type | 6% Cross-linked Agarose |
Media Type | Phenyl Sepharose HP |
Max. Pressure | 5 bar [0.5 MPa] (70 psi) |
Cytiva HiTrap™ IgG Sepharose FF
Cytiva HiTrap™ IgG Sepharose FF is easy to use with a syringe, peristaltic pump, or a chromatography system.
Cytiva HiTrap Capto Butyl
Capto Phenyl (High sub) and Capto Butyl are hydrophobic interaction chromatography (HIC) resins used in the capture and intermediate stages of protein purification
Height (Metric) | 25 mm |
---|---|
Flow Rate | < 600 cm/h |
Storage Requirements | 4 to 30 °C, 20% Ethanol |
For Use With (Application) | Hydrophobic Interaction Chromatography |
Cytiva Phenyl Sepharose™ CL-4B Gel
For immunoglobulin purification and fractionation as well as immunoprecipitation procedures
Particle Size | 45 to 165 μm |
---|---|
Ligand Type | Phenyl |
Height (Metric) | 25 mm |
pH Range | 3 to 13 |
Product Type | HiTrap Phenyl FF (High Sub) |
Material | Polypropylene |
Storage Requirements | 4°C to 30°C, 20% Ethanol |
For Use With (Application) | For Screening of Selectivity, Binding and Elution Conditions, as Well as Small Scale Purifications |
Support Type | 6% Cross-linked Agarose |
Media Type | Phenyl Sepharose 6 Fast Flow (high sub) |
Max. Pressure | 5 bar [0.5 MPa] (70 psi) |
Height (English) | 0.984 in. |
Cytiva HIC (Hydrophobic Interaction Chromatography) Media
Features high chemical stability, properties to increase productivity and epoxy coupling
Particle Size | 75 μm |
---|---|
Flow Rate | 600 cm/Hoμr |
Binding Capacity | 27 mg BSA/mL |
Storage Buffer | 20% Ethanol |
pH Range | 3 to 13 |
Quantity | 25 mL |
Storage Requirements | 4°C to 30°C |
For Use With (Application) | For Used in The Capture and Intermediate Stages of Protein PurifiCatIon |
Height (Metric) Bed | 20 cm |
Media Type | Highly Cross-Linked Agarose |
Max. Pressure | 300 kPa |
Cytiva HiTrap™ Capto™ Octyl
Columns are prepacked with Hydrophobic Interaction Chromatography (HIC) Media, used in the capture and intermediate stages of protein purification
Cytiva HiTrap Capto Butyl ImpRes
A ready-to-use column prepacked with BioProcess Capto Butyl ImpRes resins for screening and small-scale protein purification using hydrophobic interaction chromatography.
Cytiva HiTrap Capto Phenyl (High Sub)
Capto Phenyl (High sub) and Capto Butyl are hydrophobic interaction chromatography (HIC) resins used in the capture and intermediate stages of protein purification
Height (Metric) | 25 mm |
---|---|
Flow Rate | < 600 cm/h |
Storage Requirements | 4 to 30 °C, 20% Ethanol |
For Use With (Application) | Hydrophobic Interaction Chromatography |
Cytiva Untagged Column Package
Combines cation and anion exchange with size exclusion chromatography for purification of most untagged or native proteins
Cytiva HiTrap™ HIC Sepharose™ Selection Kit
Use for laboratory and intermediate process-scale separations and final-step purifications. Cytiva Life Sciences™ HiTrap™ HIC Sepharose™ Selection Kit takes full advantage of hydrophobic interaction chromatography providing highest resolution.