UV-Vis Spectrophotometers
UV-Vis Spectrophotometers
- (1)
- (6)
- (1)
- (2)
- (1)
- (2)
- (1)
- (1)
- (2)
- (1)
- (7)
- (7)
- (3)
- (2)
- (1)
- (12)
- (1)
- (17)
- (1)
- (2)
- (33)
- (2)
- (1)
- (2)
- (1)
- (1)
- (2)
- (61)
- (9)
- (2)
- (2)
- (1)
- (8)
- (1)
- (8)
- (9)
- (2)
- (2)
- (1)
- (1)
- (1)
- (2)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (4)
- (1)
- (1)
- (1)
- (1)
- (1)
- (2)
- (1)
- (1)
- (13)
- (1)
- (1)
- (1)
- (1)
- (2)
- (1)
- (35)
- (3)
- (1)
- (2)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (6)
- (1)
- (3)
- (9)
- (3)
- (2)
- (1)
- (4)
- (21)
- (1)
- (2)
- (4)
- (1)
- (11)
- (2)
- (24)
- (2)
- (2)
- (3)
- (3)
- (16)
- (2)
- (14)
- (41)
- (3)
Filtered Search Results
Thermo Scientific™ GENESYS™ 40/50 Vis/UV-Vis Spectrophotometers
For teaching labs or quality control experts who require ruggedness, ease-of-use and software capability in UV-Vis spectrophotometry.
Thermo Scientific™ Evolution™ One/One Plus UV-Vis Spectrophotometers
Thermo Scientific™ Evolution™ UV-Vis Spectrophotometers combine reliable and versatile hardware with easy-to-learn, easy-to-use Thermo Scientific™ Insight™ Pro Software. Together they will meet the diverse needs your organization requires from an analytical tool.
Thermo Scientific™ GENESYS™ 30 Visible Spectrophotometer
Perform both basic and complex analyses with the Thermo Scientific™ GENESYS™ 30 Visible Spectrophotometer, an intuitive, reliable solution for education or in the lab.
Photometric Accuracy | ±0.002 A (0 to 0.3 A), 0.5% of ABS reading (0.301 A to 2.5 A) |
---|---|
Connections | USB-A, USB-B |
Scan Speed | Automatic – up to 1200 nm/min. |
Printer Included | Thermal printer accessory with 80 mm width paper |
Noise | ≤0.001A at 0A |
Languages | English, French, German, Spanish, Italian, Portuguese, Russian, Chinese, Japanese, Korean, Thai, Arabic |
Detector Type | Silicon Photodiode |
Compartments | Accessible from top, front or side Able to accommodate cells up to 100mm pathlength Available accessory for test-tubes up to 25mm diameter and 150mm height Removable, washable sample compartment liner with magnetic placement and hold-down |
Stray Light | <0.1%T at 340 nm and 400 nm Measured using glass cutoff filters or NaNO2 at 340 nm |
Optical Design | Single Beam |
Photometric Repeatability | ± 0.002 A Measured at 1.0 A at 546 nm |
Weight (Metric) | 7.5 kg |
Wavelength Data Interval | 1 nm |
Electrical Requirements | External AC to DC converter. Voltage and Frequency (Hz) selected automatically, 100/250 V, 50/60 Hz |
Warranty | 2 years standard with 1 year extension upon registration of the instrument with Thermo Fisher Scientific within 6 months of purchase |
Photometric Range | -3A to +3A |
Wavelength Repeatability | < ±1 nm |
Spectral Bandwidth | 5 nm |
Baseline Flatness | <0.003 A, 325 to 1000 nm, smoothed |
Photometric Display | -3A to +3A, 0 to 200 000 %T, 0 to 9 999 999 C |
Type | Visible Spectrophotometer |
Dimensions (L x W x H) | 35.5x 38.5x 19.5 cm |
Wavelength Accuracy | ±2 nm |
Lamp Life | 1000 hrs. |
Keypad | Tactile rubber 23 keys with numeric keypad |
Drift | <0.002 A/hr. (At 500 nm after 2 hr. warmup.) Typical <0.004 A/hr. after 1 hr. warmup |
Wavelength Range | 325 to 1100 nm |
Product Line | GENESYS 30 |
Display | 5 in. 32-bit Color Display, 800 x 480 pixels |
Thermo Scientific™ GENESYS™ 180 UV-Vis Spectrophotometer, EU power cable
Perform UV-Vis measurements with a double beam with a reference cell position with the Thermo Scientific GENESYS 180 UV-Vis spectrophotometer.
Thermo Scientific™ BioMate™ 160 UV-Vis Spectrophotometer
Perform automated measurements of nucleic acids, proteins and cell cultures with the Thermo Scientific BioMate 160 UV-Vis spectrophotometer.
Spectral Bandwidth | 2 nm |
---|
Thermo Scientific™ Evolution™ Pro UV-Vis Spectrophotometers
Thermo Scientific™ Evolution™ UV-Vis Spectrophotometers combine reliable and versatile hardware with easy-to-learn, easy-to-use Thermo Scientific™ Insight™ Pro Software. Together they will meet the diverse needs your organization requires from an analytical tool.
Spectral Bandwidth | 0.5, 1.0, 1.5, 2.0, 4.0 nm Selectable |
---|---|
Product Line | Evolution Pro |
Thermo Scientific™ SPECTRONIC 200™ Spectrophotometer
Thermo Scientific™ SPECTRONIC™ 200 is the new standard for rugged, simple-to-use visible spectrophotometers for teaching and routine applications.
Connections | USB-B for connection to a remote computer USB-A for connection to a printer or USB memory device |
---|---|
Width (English) | 15.3 in. |
Printer Included | External printer support: Epson TM-T88V |
Languages | English, French, German, Spanish, Italian, Chinese, Japanese, Korean, Thai |
Photometric Readout | ABS, %T, Concentration (standard or custom units) |
Light Source | Tungsten Halogen |
Width (Metric) | 39 cm |
Includes | Two Cuvet Racks; Ten 1cm plastic cuvets |
Detector Type | 2048-element CCD |
Compartments | Removable, washable sample compartment |
Stray Light | <0.2%T (with SPECTRONIC standard SRM 400 filter) |
Optical Design | Single Beam |
Photometric Repeatability | ±0.03 A at 0.3 A |
Weight (Metric) | 5.2 kg |
Height (English) | 3.6 in. |
Height (Metric) | 16 cm |
Electrical Requirements | Selected automatically, 100/240 V, 50/60Hz |
Depth (English) | 11.8 in. |
Photometric Range | -0.3 to 2.5Å |
Wavelength Repeatability | ±1nm |
Data Interval for Scanning | 1 nm on-board, 0.5 nm under computer control |
Spectral Bandwidth | <4 nm |
Photometric Display | -0.3A - 2.5A; 0 - 125%T |
Wavelength Accuracy | ±2 nm |
Lamp Life | 1000 hrs. |
Depth (Metric) | 30 cm |
Keypad | Sealed tactile rubber |
Container Type | Single cell holder for square cuvettes and for test tubes |
Weight (English) | 9.7 lb. |
Interface | USB-B; USB-A |
Wavelength Range | 340 to 1000 nm |
Display | 3.5 in. Color Graphic TFT LCD |
Cole-Parmer™ Jenway™ 74 Series Visible and UV/Visible Scanning Spectrophotometers with CPLive™ Connectivity
Get cloud-based secure storage of your results and protocols with Jenway 74 Series Visible and UV/Visible Scanning Spectrophotometers with CPLive Connectivity
Connections | 2 x USB-A, 1 x USB-B, Ethernet RJ45 |
---|---|
Photometric Range | 0 to 199.9 %T |
Wavelength Repeatability | ± 0.5 nm |
Spectral Bandwidth | 5 nm |
Absorbance Range | -0.3 to +2.5 A |
Pathlength | 10 to 100 mm |
Concentration | -300 to 9999 |
Includes | 10GB memory |
Detector Type | Silicon Photodiode |
Type | Spectrophotometer |
Dimensions (L x W x H) | 50 x 28 x 15.6 cm |
Wavelength Accuracy | ± 2 nm |
Photometric Accuracy Including Standard Tolerance | ±1%T |
Voltage | 100/240 V |
Absorbance Accuracy | ±0.01 A at 1.000 A |
Certifications/Compliance | CE |
Optical Design | Single |
Hertz | 50/60 Hz |
Display | Touchscreen |
Thermo Scientific™ SPECTRONIC™ 200 Spectrophotometer
Thermo Scientific™ SPECTRONIC™ 200 is the standard for rugged, simple-to-use visible spectrophotometers for teaching and routine applications.
Bibby Scientific™ Jenway™ 7305 Model Spectrophotometer
Small footprint. Jenway™ 7305 Model Spectrophotometer contains icon driven software with improved navigation system for easy and intuitive usability.
Biochrom Biowave 3
The Biowave 3 offers all the capabilities of a research grade spectrophotometer with a robust design and a reasonable cost make it great for students.
Shape | Round |
---|---|
Width (English) | 10 in. |
Photometric Linearity | ±1.3% or ±0.008 A (Whichever is Greater at 546 nm) |
Noise | ±0.005 peak to peak ±0.002 RMS |
Languages | English, French, German, Spanish, Italian, Chinese, Japanese |
For Use With (Application) | UV/Vis Spectrophotometry |
Light Source | Xenon Flash |
Width (Metric) | 260 mm |
Detector Type | Twin CMOS Array |
For Use With (Equipment) | Microvolume Cuvettes |
Voltage | 100/115/220/230 V |
Stray Light | >0.5 %T 340 nm |
Photometric Repeatability | ±0.002 A to 0.5 A (at 546 nm) |
Weight (Metric) | 3 kg |
Height (English) | 3.9 in. |
Height (Metric) | 100 mm |
Beam Center Height | 15 mm |
Depth (English) | 15.3 in. |
Monochromator | Flat Grating |
Photometric Range | -0.3 to 2.5 A, 0.3 to 199 %T |
Wavelength Repeatability | ±1 nm |
Spectral Bandwidth | 5 nm |
Type | UV-Vis Spectrophotometer |
Wavelength Accuracy | ±2 nm |
Depth (Metric) | 390 mm |
Weight (English) | 6.6 lb. |
Wavelength Range | 190 to 1100 nm |
Product Line | Biowave 3 |
Display | Graphic LCD |
Biochrom BioDrop μLITE+
The BioDrop μLITE+ microvolume sample port uses no moving parts. This means that the instrument provides excellent reproducibility without the need for expensive calibration, and no concern your results may stray over time.
Lovibond™ Colorimeter Tablet Reagent: DPD No. 1
Use with MC500, MD600, SC450, MD100 colorimeters, SP600 spectrophotometer, Pool Control 9, AquaPRO3 Pool and AquaPRO6 Pool photometers and Scuba IIElectronic Pool Tester
Lovibond™ Colorimeter Tablet Reagent: DPD No. 3
For use with MC500, MD600, SC450, MD100 colorimeters, SP600 spectrophotometer, Pool Control 9, AquaPRO3 Pool and AquaPRO6 Pool photometers and Scuba II Electronic Pool Tester.
Thermo Scientific™ Orion™ AquaMate Vis and UV-Vis Spectrophotometers
Optimized for your water analysis needs AquaMate 7100 Vis and AquaMate 8100 UV-Vis Spectrophotometers provide fast and reliable results
Photometric Accuracy | ±0.002 A at 0.5 A, ±0.004 A at 1.0 A, ±0.008 A at 2.0 A |
---|---|
Connections | Single USB-A Export data to network or PC via USB, Ethernet, or Wi-Fi USB adaptor, available Print via USB, Ethernet or Wi-Fi USB adaptor available |
Height (Metric) | 19.5 cm |
Electrical Requirements | External AC to DC converter. Voltage and Frequency (Hz) selected automatically, 100/240 V, 50/60 Hz |
Warranty | 1 Year |
Length (Metric) | 35.5 cm |
Noise | (RMS at 500 nm 60 consecutive measurements) ≤0.00020A at 0A at 260 and 500 nm ≤0.00030A at 1A at 260 and 500 nm ≤0.00040A at 2A at 260 and 500 nm |
Wavelength Repeatability | < ±0.2 nm |
For Use With (Application) | Water and Waste Water Analysis |
Width (Metric) | 38.5 cm |
Detector Type | Dual Silicon Photodiodes |
Dimensions (L x W x H) | 35.5 x 38.5 x 19.5 cm |
Wavelength Accuracy | ±0.5 nm |
Depth (Metric) | 35.5 cm |
Compartments | Accessible from top, front or side Able to accommodate cells up to 100 mm cells Available accessory for test tubes up to 25 mm diameter and 150 mm height Removable, washable sample compartment liner with magnetic placement and hold-down |
Keypad | Glove- friendly touchscreen |
Certifications/Compliance | CE / TUV |
Optical Design | Double Beam |
Photometric Repeatability | ±0.001A at 1A measured at 1.0A at 546 nm |
Interface | Glove friendly touch-screen |
Weight (Metric) | 7.5 kg |
Wavelength Data Interval | 0.2 nm, 0.5 nm, 1 nm, 2 nm, 5 nm |
Display | 7 in. High Definition Color Touchscreen, Fixed, 800 x 1280 pixels |